Intelligent Integrated Power Supply System-PSDB

PSDB integrated AC/DC system with unified monitoring for large-capacity substations.

Download Datasheet/下载规格书
Rated input voltage

AC 380V±20%

AC input frequency

50Hz±10%

Rated AC output voltage

AC 380V, AC 220V

Rated AC output current

100A, 160A, 200A, 300A, 400A, 630A

Rated DC output voltage

220VDC, 110DC, 48VDC, 24VDC

Rated DC output current

30A, 40A, 60A, 80A, 100A, 150A, 200A

Accumulator capacity

100Ah, 150Ah, 200Ah, 300Ah, 400Ah, 500Ah, 600Ah, 800Ah, 1000Ah, 1500Ah, 2000Ah……

Stable pressure accuracy

≤±0.5%

Stable flow accuracy

≤±1%

Ripple factor

≤±0.5%

UPS power rating

2KVA, 3KVA, 5KVA, 10KVA, 15KVA, 20KVA, 30KVA

UPS output voltage

AC 220V, AC380V±2%

UPS output frequency

50HZ±1%

The UPS output is required for the waveform distortion

5%(Linear load)

UPS dynamic response

5%(0%~100% load)

DC to transform the rated output voltage

48VDC、24VDC

DC conversion of the rated output current

20A, 30A, 40A, 60A, 80A, 100A, 150A

Insulation strength

>10MΩ 2kV AC for one minute, no flashover, no breakdown

Operate mode

Continuous long-term operation

Cooling-down method

Intelligent temperature control, air cooling, efficient and natural cooling

Brief Introduction

PSDB series intelligent integrated power supply system is designed for a variety of large capacity users of AC and DC integrated power supply system. The integrated AC and DC power supply system adopts a layered distribution architecture. The station AC power supply, DC operation power supply, power special UPS and power special inverter (INV), DC/DC conversion power supply (DC/DC) and other equipment are designed and configured in an integrated way. Through a unified intelligent network platform, the centralized power supply and unified monitoring and management of the substation power supply are realized. Then the on-line state detection is realized. Its operating conditions and information data can be displayed and converted into standard model data through the integrated monitoring device, which is connected to the station control layer switch of the local automation system in the standard DL/T 860(IEC61850) format, and uploaded to the remote control center. The station AC power supply is composed of AC panel monitoring module, AC monitoring module, switch quantity monitoring module,
automatic transfer switch ATS, incoming plastic-case switch, current transformer, intelligent power meter and feeder circuit breaker. It realizes the power distribution and protection from station power AC output to rectifier module, and fundamentally guarantees the safe and reliable switching of power supply. Dc operating power supply is a power supply that can reliably supply power to all control loads and various power loads in the substation under normal and accident conditions. The DC power system consists of DC panel monitoring module, rectifier module, buck module, battery inspection module, insulation monitoring module, switch quantity monitoring module, power distribution unit, and battery pack.

Suitable for power plants, hydropower stations, all kinds of substations, switching stations and other users using DC equipment, to provide a stable and reliable power supply for a variety of network communication instruments and equipment, and to ensure the safe and reliable operation of communication equipment.

Model Meaning

① SEE
② AC and DC integrated power supply
③ Battery capacity (Ah), two batteries ×2
④ DC screen rated output voltage (DC) :220V, 110V
⑤ UPS Code
⑥ UPS capacity: 2KVA, 3KVA, 5KVA, 10KVA, 15KVA, 20KVA, 30KVA
⑦ UPS rated output voltage (AC) : 220V, 380V
⑧ DC conversion module code
⑨ DC conversion module rated output voltage (DC) : 48V, 24V
⑩ DC conversion module output current: 20A, 30A, 40A, 60A, 80A, 100A, 150A

National Standards
DL/T 459-2017 DC power supply equipment for electric power;
DL/T 637-2019 Fixed valve-controlled lead-acid battery for electric power;
DL/T 724-2000 Technical specification for operation and maintenance of accumulator DC power supply device for power system;
DL/T 781-2001 High frequency switching rectifier module for electric power;
DL/T 856-2004 DC power supply monitoring device for electric power;
DL/T 857-2004 Technical conditions for rectifier inverters for batteries in power plants and substations;
DL/T 1392-2014 DC power system insulation monitoring device technical conditions;
DL/T 5044-2014 Power engineering DC power system design technical specification;
GB/T 19826-2014 Power engineering DC power equipment general technical conditions and safety requirements;
GB/T 17626.18-2016 Electromagnetic compatibility test and measurement techniques Damping oscillation wave immunity test.

Rated input voltage

AC 380V±20%

AC input frequency

50Hz±10%

Rated AC output voltage

AC 380V, AC 220V

Rated AC output current

100A, 160A, 200A, 300A, 400A, 630A

Rated DC output voltage

220VDC, 110DC, 48VDC, 24VDC

Rated DC output current

30A, 40A, 60A, 80A, 100A, 150A, 200A

Accumulator capacity

100Ah, 150Ah, 200Ah, 300Ah, 400Ah, 500Ah, 600Ah, 800Ah, 1000Ah, 1500Ah, 2000Ah……

Stable pressure accuracy

≤±0.5%

Stable flow accuracy

≤±1%

Ripple factor

≤±0.5%

UPS power rating

2KVA, 3KVA, 5KVA, 10KVA, 15KVA, 20KVA, 30KVA

UPS output voltage

AC 220V, AC380V±2%

UPS output frequency

50HZ±1%

The UPS output is required for the waveform distortion

5%(Linear load)

UPS dynamic response

5%(0%~100% load)

DC to transform the rated output voltage

48VDC、24VDC

DC conversion of the rated output current

20A, 30A, 40A, 60A, 80A, 100A, 150A

Insulation strength

>10MΩ 2kV AC for one minute, no flashover, no breakdown

Operate mode

Continuous long-term operation

Cooling-down method

Intelligent temperature control, air cooling, efficient and natural cooling

评价

目前还没有评价

成为第一个“Intelligent Integrated Power Supply System-PSDB” 的评价者

您的邮箱地址不会被公开。 必填项已用 * 标注

FAQ

What IP rating do you recommend for outdoor distribution boxes in Africa?

For outdoor use in tropical or desert climates, we recommend IP54 or IP65 enclosures with anti-corrosion coating. Our TBC and LCB series are available in IP65 upon request.

Yes. Our LVDB low voltage distribution boards support copper busbars rated from 400A to 2500A. Custom configurations with specific breaker brands can be arranged for bulk orders.

Our MU32, MU33, and MU34 CT metering boxes comply with IEC 61439 and local utility requirements. CE certification is available for all exports.

Standard products ship within 15-20 working days after deposit. Customized orders typically require 30-45 working days depending on complexity.

We offer detailed installation manuals, and for large EPC projects, we can arrange factory training or remote commissioning support.

滚动至顶部

Great! We have received your message. Our staff will contact you within 10 minutes during working hours.

We are unable to process your submission. Please try again.

×

Privacy Policy

We respect your privacy and are committed to protecting your personal data. This privacy policy explains how we collect, use, and safeguard the information you provide through our contact form.

Information We Collect
When you submit a message via our contact form, we collect: Your name, email address, and the content of your message.

How We Use Your Information
We use this information solely to respond to your inquiries and provide customer support. We will never sell, rent, or share your personal data with third parties for marketing purposes.

Data Retention
Your submitted information is retained in our email system for as long as necessary to handle your request and for legitimate business record-keeping.

Your Rights
You have the right to request access to, correction of, or deletion of your personal data at any time. Contact us at [wyz@wuliansee.com].

Last updated: [2026/08/12]